SPECIFICATION CONTROL DRAWING Title 44A022X Date Revision TWO CONDUCTOR CABLE, RADIATION-CROSSLINKED POLYALKENE INSULATED, 01-20-04 B UNSHIELDED, UNJACKETED, LIGHTWEIGHT,GENERAL PURPOSE, 1000 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 44 and MIL-W-81044 as applicable. COMPONENT WIRES - 44A021X CABLE CONSTRUCTION DETAILS PART NUMBER 1/ CONDUCTOR SIZE (AWG) 44A022X-26-* 44A022X-24-* 44A022X-22-* 44A022X-20-* 44A022X-18-* 44A022X-16-* 44A022X-14-* 44A022X-12-* 44A022X-10-* 44A022X- 8-* 44A022X- 6-* 44A022X- 4-* 26 24 22 20 18 16 14 12 10 8 6 4 OUTSIDE DIAMETER (inches) NOMINAL .080 .092 .108 .124 .146 .162 .196 .234 .292 .412 .508 .616 MAXIMUM WEIGHT (lbs/1000 ft) MAXIMUM .085 .097 .114 .130 .152 .169 .203 .242 .302 .433 .533 .647 3.2 4.8 7.0 10.4 15.4 19.6 29.6 44.4 71.7 125. 190. 302. CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 1000 volts (rms) at sea level INSULATION FLAWS: Spark Test, 4.0 kV (rms) at 3 kHz Impulse Dielectric Test, 8.0 kV (peak) The "X" in the part numbers above shall be replaced with a conductor material designator as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high strength copper alloy The "*" in the part numbers above shall be replaced by color code designators with a slash separating component wire colors: 1/ Example: AWG 20, tin-coated copper wires; black and white components: 44A0221-20-0/9 NOTE: Nominal values are for information only Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Page 1 of 1 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Wire & Cable 501 Oakside Avenue Redwood City, CA 94063-3800 Phone: 1-800-227-8816 Fax: 1-650-361-6297